KB-BT(35KV)35KV Busbar heat shrink tube

Materials: Corss-linked modified polyolefin
˙Operating temperature range:-40℃~125℃
˙Shrink temperature:: above 70℃
˙Shrink ratio:: 2:5:1
˙Features: High-voltage resistance, corrosion resistance, high insulation
˙Applications: Suitable for insulation protection for transformer station buses and high/low voltage switch cubicle buses; compacts the structure of the switch cubicle (reduces the distance in between) and prevents accidental short circuit incidents

Items Performance Indicators Typical Value
Tensile strength GB/T1040 ≧10.4MPa
Tensile strength after aging 130℃ x 168 hrs ≧7.3MPa
Elongation at break GB/T1040 ≧300%
Elongation at break after aging 130℃ x 168 hrs ≧100%
Thermal shock 160℃ x 4 hrs no cracks pass
Bendability at low temperature -40℃ x 4 hrs no cracks pass
Insulation Breakdown voltage GB/T1408.1 ≧15Kv/mm
Volume resistivity GB/T1040 ≧4.3 x 1014 Ω. cm

 

Size As supplied After recovery Packaged Length
ID/mm Wall Thickness/mm  ID/mm Wall Thickness/mm M
35KV 30/15
35KV 35/18
35KV 40/20
35KV 50/25
35KV 60/30
35KV 65/33
35KV 70/35
35KV 75/38
35KV 80/40
35KV 100/50
35KV 120/60
35KV 150/75
35KV 180/90
35KV 210/105
35KV 230/115
30 ± 1.0
35 ± 1.0
40 ± 1.0
50 ± 2.0
60 ± 2.0
65 ± 2.0
70 ± 2.0
75 ± 2.0
80 ± 3.0
100 ± 4.0
120 ± 4.0
150 ± 4.0
185 ± 5.0
210 ± 5.0
230 ± 5.0
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
15
18
20
25
30
33
35
38
40
50
60
75
90
105
115
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
Items Performance Indicators Typical Value
Tensile strength GB/T1040 ≧10.4MPa
Tensile strength after aging 130℃ x 168 hrs ≧7.3MPa
Elongation at break GB/T1040 ≧300%
Elongation at break after aging 130℃ x 168 hrs ≧100%
Thermal shock 160℃ x 4 hrs no cracks pass
Bendability at low temperature -40℃ x 4 hrs no cracks pass
Insulation Breakdown voltage GB/T1408.1 ≧15Kv/mm
Volume resistivity GB/T1040 ≧4.3 x 1014 Ω. cm

 

Size As supplied After recovery Packaged Length
ID/mm Wall Thickness/mm  ID/mm Wall Thickness/mm M
35KV 30/15
35KV 35/18
35KV 40/20
35KV 50/25
35KV 60/30
35KV 65/33
35KV 70/35
35KV 75/38
35KV 80/40
35KV 100/50
35KV 120/60
35KV 150/75
35KV 180/90
35KV 210/105
35KV 230/115
30 ± 1.0
35 ± 1.0
40 ± 1.0
50 ± 2.0
60 ± 2.0
65 ± 2.0
70 ± 2.0
75 ± 2.0
80 ± 3.0
100 ± 4.0
120 ± 4.0
150 ± 4.0
185 ± 5.0
210 ± 5.0
230 ± 5.0
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
1.9 ± 0.5
15
18
20
25
30
33
35
38
40
50
60
75
90
105
115
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
4.0 ± 0.3
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15


Give Us A Message

* Name
Tel
* Email
* Message